Zenessis pe Facebook Zenessis pe Twitter Zenessis pe Google + Romana English Russian
 
 

ESE 20-120 MD

 
 
ESE 20-120 MD
Input voltage
380V/400V/415V(line to line)
 
Input frequency
50/60Hz
 
Power factor
>0.99
 
Input voltage range
-20%~+25%
 
Input frequency range
40-70HZ
 
 
COD: ESE 20-120 MD
 
 
 
TECHNICAL DETAILS
 

BATERRIES

Batteries voltage

Loading power

Charging voltage accuracy

BYPASS

* To use the term bypass, it was accepted in common terminology meaning bypass circuit.

Bypass voltage - 380V/400V/415V, three phase 

                           220V/230V/240V, one phase

Bypass voltage range - -20%-+15%, full load, settable

Bypass circuit overload capacity - 125%, long time operation 

                                                      125%< load <130%, last for more than 1 hour 

                                                       130%

                                                        >1000%, last for more than 100ms 

 

OUTPUT

Output Voltage -  380V/400V/415V, three phase 

                            220V/230V/240V, one phase 

Voltage accuracy - ±0.5% (balance load),±1% (unbalance load)

THD - THD<1%(linear load),THD<5%(nonlinear load)

Power factor - 0.8

Phase tolerance - 120°±0.5° (balance and unbalance load)

Crest factor - 3:1

Overload capacity - 105%,long time operation 

                                 110%, transfer to bypass after 1hour 

                                 125%, transfer to bypass after 10 minutes 

                                 150%, transfer to bypass after 1 minute 

                                  >150%, transfer to bypass after 200ms 

SYSTEM

System efficiency - ECO mode: 99%

Efficiency in battery mode - 95%

Display: LCD+LED, Touch screen and keyboard

IP class - IP20

Interface -  RS232,RS485,Dry contacts,SNMP card,EPO,Generator interface , EPO-emergency power off button

Installation /connections-connections on the top or bottom

Operating temperature - 0-40C

Storage temperature - -25C~70C

Relative humidity - 0-95% (non-comdensing)

Noise - <55dB

Weight -  6 -module cabinet / RM060/10, RM090/15, RM120/20 / 150KG

              10-module cabinet / RM100/10, RM150/15, RM200/20 / 180KG

               PM20 / 20KVA: 22KG

Dimensions - 6-module cabinet / 600*900*1600

                      10-module cabinet / 600*900*2000

                      Module / 400*600*133 (/20KVA)

 

 

 

 

 

 

SIMILAR PRODUCTS

 
LATEST NEWS
 
Baudouin , new motors in our portfolio
28
 
FEB
2017
Starting with 2017, Endress Group Romania introduces in it’s portfolio of produced current generators, the Moteurs Baudouin products.
Next generation of Auto Mains Failure (AMF) gen-set controller
07
 
NOV
2016
The new modules of InteliLite AMF 20/25 range can be used for the command and control of the gen-sets, for the ONSITE working, but for OFFSITE working, too. These can be remotely commissioned and controlled , but can be monitored through its own server.
 
NEWSLETTER SUBMISION
Insert email address
 
CONTACT ZENESSIS
Tel.: +40.21.350.09.95
Email: office@endress-group.ro
 
© Copyright 2018 Zenessis