Input voltage
220 VAC
 
Input frequency
50/60 Hz
 
Capacity ( kVA / kW )
10/9
 
Operating temperature for UPS
0°C ÷ 40°C
 
Dimensions (WxDxH)
438x704x215.5 mm(5U)
 
Weight of battery module
63 kg
 
 
COD: ZRM 10K
 
 
 
TECHNICAL DETAILS
 

Uninterruptible power supply 

ZRM Series 1 - 2 -3 - 6 - 10 KVA

  • True On-Line Double Conversion Technology 
  • Automatic Bypass (Static Switch) 
  • Communication: USB, RS-232, DryContact for UPS (Uninterruptible Power Supply) and load supervision and control.
  • Ethernet Interface for computer-network communication with SNMP protocol support
  • LCD Panel displays UPS and power parameters.
  • Software controlled output sockets – enable managing groups of load.
  • Small dimensions 
  • ECO-Mode
  • Efficiency up to 99%.
  • Backup time extension possibility
  • Automatic diagnostics
  • High input power factor
  • High output power factor (PF=0.9) allows load of versatile characteristics to be connected.
  • Wide input voltage range for normal mode ensures that the batteries are used only if necessary 
  • Wide input frequency range
  • Easy operation - microprocessor control and fully automatic mode ensure maintenance-free work.
  • Automatic startup
  • Advanced Battery Management
  • Battery startup
  • PWM modulation method; the output voltage has always stable parameters, independent of input disturbances and load characteristics.
  • Advanced power management software provides full control of UPS.
  • User configurable settings – nominal voltages, frequencies, preferred operating modes, ways of communication – widens the range of possible applications.
  • REPO – enables remote emergency power off, in case of emergency.
  • Hot Standby redundancy available for 6 and 10 kVA models 
  • Power Distribution Unit (PDU) for 6 and 10 kVA units, terminal board with IEC-320 sockets and integrated maintenance bypass.
  • Excellent voltage quality is provided by IGBT inverter and high frequency.
  • High overload capacity
     

 

 

SIMILAR PRODUCTS

Input voltage 220 VAC
Input frequency 50/60 Hz
Capacity ( kVA / kW ) 3/2.7
Operating temperature for UPS 0°C ÷ 40°C
Dimensions (WxDxH) 440x608x87 mm (2U)
Weight of battery module 33.3
 
Input voltage 230 VAC
Input frequency 50/60 Hz
Capacity ( kVA / kW ) 6/5.4
Operating temperature for UPS 0°C ÷ 40°C
Dimensions (WxDxH) 438x698x129 mm( 3U)
Weight of battery module 42 kg
 
Input voltage 220 VAC
Input frequency 50/60 Hz
Capacity ( kVA / kW ) 2/1.8
Operating temperature for UPS 0°C ÷ 40°C
Dimensions (WxDxH) 440x438x87 mm (2U)
Weight of battery module 27.5
 
 
LATEST NEWS
 
Baudouin , new motors in our portfolio
28
 
FEB
2017
Starting with 2017, Endress Group Romania introduces in it’s portfolio of produced current generators, the Moteurs Baudouin products.
Next generation of Auto Mains Failure (AMF) gen-set controller
07
 
NOV
2016
The new modules of InteliLite AMF 20/25 range can be used for the command and control of the gen-sets, for the ONSITE working, but for OFFSITE working, too. These can be remotely commissioned and controlled , but can be monitored through its own server.
 
NEWSLETTER SUBMISION
Insert email address
 
CONTACT ZENESSIS
Tel.: +40.21.350.09.95
Email: office@endress-group.ro
 
© Copyright 2018 Zenessis