Zenessis pe Facebook Zenessis pe Twitter Zenessis pe Google + Romana English Russian
 
 

Diesel generator set ESE 275 TD

 
 
Diesel generator set ESE 275 TD
Power (kVA)(ESP / PRP)
275/250
 
Power (kW)(ESP / PRP)
220/200
 
Speed(rpm)
1500
 
Standard voltage (V)
400/230
 
Power factor (cos phi)
0,8
 
Amperage (Amp)
360
 
 
COD: ESE 275 TD
 
 
 
TECHNICAL DETAILS
 

STANDARD EQUIPMENT

 

*Metallic command & control panel with measurements & control devices, degree protection – IP 54

*Static battery charger

*Dynamic batteries charging alternator.

*Temperature controlled heater for the coolant

*Oversized starting battery

*Emergency stop button

*Chassis with fuel tank sized for 8 hours autonomy

*Anti vibration dampers

*Fuel level measuring device

*Protected electrical tubing trails & gland

*Residential silencer

 

DIESEL ENGINE DOOSAN P126TI

Number of cylinders - 6

Aspiration - TI

Cylinder capacity - 11.1 L

Max.Power kW(ps)/rpm (DIN6270B) - 294(400) / 2,100

Dimensions - 1,383 x 870 x 1,207

Weight without fluids - 910 kg

 

 

 

ALTERNATOR

 

*Synchronous alternator (generator), self-excited, 4-poles, brushless, oversized

*Protection class H

*Protection degree IP23

*Excitation system equiped with AVR (Automatc Voltage Regulator) which constantly adjusts the output voltage - ÷5%

 

CONTROL MODULE

                               

 

*Devices

InteliLiteNT AMF 25 or DSE 6020 control module

Static battery charger

Emergency stop button & fuses for the control circuits

*Tools

Engine: engine speed; oil pressure; coolant temperature; operating time; battery voltage; configurable synchronization.

Generator: voltage (L-L, L-N); current (L1-L2-L3); frequency.

Main network: voltage (L-L, L-N); frequency; mains ready; mains enabled; generating set ready; generating set enabled..

*Circuits protections

Warnings:charge failure; under / over battery voltage; fail to stop; under / over generator voltage; under / over generator frequency; under / over speed; low oil level; high coolant temperature.

Shut downs: fail to start; emergency stop; low oil pressure; high coolant temperature; under / over speed; under / over generator frequency; under / over generator voltage; oil pressure sensor open; coolant temperature sensor open.

Electrical trip: generator overcurrent 

 

 

CANOPY

 

1.Steel structure, built – in fuel tank; the canopy is made of steel sheet, galvanized, painted in electrostatic field

2.Emergency stop button

3.The control panel is mounted on the baseframe; located on the right side of the generator set.

4.Corossion resistant locks and hinges.

5.The oil can be drained by means of a valve and a hose.

6.Exhaust system inside the canopy.

7.Large access doors for easy maintenance.

8.Base frame fuel tank

9.Lifting points

10.Sound proofing materials / sound insulation, double circuit inserted in the canopy

11.Residential silencer (sound emissions attenuation -51 dB, measured at 7 m)

 

OPTIONAL EQUIPMENT

*Anti-condensation electric panels heating system

*Fuel /oil heating system

*Coolant heating circulation pump

*Oil drain pump

*Remote control & monitoring system

*Load transfer panel (source reversing) AAR 3 / 4 poles or motorized

*Circuit breaker (CB) 3 / 4 poles or motorized

*Bypass panel – ENDRESS patented invention – OSIM 0010 / 2012 Brevet

*Remote Radiator

 *Trailer

 

SIMILAR PRODUCTS

Power (kVA)(ESP / PRP) 510 / 460
Power (kW)(ESP / PRP) 408 / 368
Speed(rpm) 1500
Standard voltage (V) 400 / 230
Power factor (cos phi) 0,8
Amperage (Amp) 664
 
Power (kVA)(ESP / PRP) 485/425
Power (kW)(ESP / PRP) 388/340
Speed(rpm) 1500
Standard voltage (V) 400/230
Power factor (cos phi) 0,8
Amperage (Amp) 613
 
Power (kVA)(ESP / PRP) 410/375
Power (kW)(ESP / PRP) 328/300
Speed(rpm) 1500
Standard voltage (V) 400/230
Power factor (cos phi) 0,8
Amperage (Amp) 541
 
 
LATEST NEWS
 
Baudouin , new motors in our portfolio
28
 
FEB
2017
Starting with 2017, Endress Group Romania introduces in it’s portfolio of produced current generators, the Moteurs Baudouin products.
Next generation of Auto Mains Failure (AMF) gen-set controller
07
 
NOV
2016
The new modules of InteliLite AMF 20/25 range can be used for the command and control of the gen-sets, for the ONSITE working, but for OFFSITE working, too. These can be remotely commissioned and controlled , but can be monitored through its own server.
 
NEWSLETTER SUBMISION
Insert email address
 
CONTACT ZENESSIS
Tel.: +40.21.350.09.95
Email: office@endress-group.ro
 
© Copyright 2018 Zenessis