Diesel generator set ESE 115 DWR
The current generator on diesel ESE 115 DWR produced by Endress Group Romania under Zenessis brand, equipped with DeWerk DW57TA motor, alternator AFA115 and control system DKG 309, which provide generator starting, the control of parameters, in automatic or manually working. The generator can be provided with remote control and monitoring, as well as other options. The guarantee of the Zenessis current generators is 36 months, for a limit of 2000 operating hours.
STANDARD EQUIPMENT
*Metallic command & control panel with measurements & control devices, degree protection – IP 54
*Static battery charger
*Dynamic batteries charging alternator.
*Temperature controlled heater for the coolant
*Oversized starting battery
*Emergency stop button
*Chassis with fuel tank sized for 8 hours autonomy
*Anti vibration dampers
*Fuel level measuring device
*Protected electrical tubing trails & gland
*Residential silencer
ALTERNATOR
*Synchronous alternator (generator), self-excited, 4-poles, brushless, oversized
*Protection class H
*Protection degree IP21
*Excitation system equiped with AVR (Automatic Voltage Regulator) which constantly adjusts the output voltage - ÷5%
CONTROL MODULE
*Devices
DKG 309 control module
Static battery charger
Emergency stop button & fuses for the control circuits
Differential protection overcurrent
*Tools
Engine: engine speed; oil pressure; coolant temperature; operating time; battery voltage; configurable synchronization.
Generator: voltage (L-L, L-N); current (L1-L2-L3); frequency.
Main network: voltage (L-L, L-N); frequency; mains ready; mains enabled; generating set ready; generating set enabled.
*Circuits protections
Warnings:charge failure; under / over battery voltage; fail to stop; under / over generator voltage; under / over generator frequency; under / over speed; low oil level; high coolant temperature.
Shut downs: fail to start; emergency stop; low oil pressure; high coolant temperature; under / over speed; under / over generator frequency; under / over generator voltage; oil pressure sensor open; coolant temperature sensor open.
Electrical trip: generator overcurrent
CANOPY
1.Steel structure, built – in fuel tank; the canopy is made of steel sheet, galvanized, painted in electrostatic field
2.Emergency stop button
3.The control panel is mounted on the baseframe; located on the right side of the generator set.
4.Corossion resistant locks and hinges.
5.The oil can be drained by means of a valve and a hose.
6.Exhaust system inside the canopy.
7.Large access doors for easy maintenance.
8.Base frame fuel tank
9.Lifting points
10.Sound proofing materials / sound insulation, double circuit inserted in the canopy
11.Residential silencer (sound emissions attenuation -51 dB, measured at 7 m)
OPTIONAL EQUIPMENT
*Anti-condensation electric panels heating system
*Fuel /oil heating system
*Coolant heating circulation pump
*Oil drain pump
*Remote control & monitoring system
*Load transfer panel (source reversing) AAR 3 / 4 poles or motorized
*Circuit breaker (CB) 3 / 4 poles or motorized
*Bypass panel – ENDRESS patented invention – OSIM 0010 / 2012 Brevet
*Remote Radiator
*Trailer